FlawAtlas
Search the atlas
CVE-2024-57986 High

HID: core: Fix assumption that Resolution Multipliers must be in Logical Collections

In the Linux kernel, the following vulnerability has been resolved: HID: core: Fix assumption that Resolution Multipliers must be in Logical Collections A report in 2019 by the syzbot fuzzer was found to be connected to two errors in the HID core associated with Resolution Multipliers. One of the errors was fixed by commit ea427a222d8b ("HID: core: Fix deadloop in hid_apply_multiplier."), but the other has not been fixed. This error arises because hid_apply_multipler() assumes that every Resolution Multiplier control is contained in a Logical Collection, i.e., there's no way the routine can ever set multiplier_collection to NULL. This is in spite of the fact that the function starts with a big comment saying: * "The Resolution Multiplier control must be contained in the same * Logical Collection as the control(s) to which it is to be applied. ... * If no Logical Collection is * defined, the Resolution Multiplier is associated with all * controls in the report." * HID Usage Table, v1.12, Section 4.3.1, p30 * * Thus, search from the current collection upwards until we find a * logical collection... The comment and the code overlook the possibility that none of the collections found may be a Logical Collection. The fix is to set the multiplier_collection pointer to NULL if the collection found isn't a Logical Collection.

Exploit probability 0.3%
Published February 27, 2025
Required by Not available
Last source change August 12, 2026

02 / AFFECTED SOFTWARE

Affected packages

Linux Kernel
Unknown Unknown

03 / CONNECTIONS

Connected vulnerabilities

04 / EVIDENCE

Source records

Open Source Vulnerabilities CVE-2024-57986

In the Linux kernel, the following vulnerability has been resolved: HID: core: Fix assumption that Resolution Multipliers must be in Logical Collections A report in 2019 by the syzbot fuzzer was found to be connected to two errors in the HID core associated with Resolution Multipliers. One of the errors was fixed by commit ea427a222d8b ("HID: core: Fix deadloop in hid_apply_multiplier."), but the other has not been fixed. This error arises because hid_apply_multipler() assumes that every Resolution Multiplier control is contained in a Logical Collection, i.e., there's no way the routine can ever set multiplier_collection to NULL. This is in spite of the fact that the function starts with a big comment saying: * "The Resolution Multiplier control must be contained in the same * Logical Collection as the control(s) to which it is to be applied. ... * If no Logical Collection is * defined, the Resolution Multiplier is associated with all * controls in the report." * HID Usage Table, v1.12, Section 4.3.1, p30 * * Thus, search from the current collection upwards until we find a * logical collection... The comment and the code overlook the possibility that none of the collections found may be a Logical Collection. The fix is to set the multiplier_collection pointer to NULL if the collection found isn't a Logical Collection.

View original source

05 / REFERENCES

Further evidence